dedicated cmr software analysis tool Search Results


90
TOMTEC IMAGING SYSTEMS GMBH cmr feature tracking software image-arena 4.6
Cmr Feature Tracking Software Image Arena 4.6, supplied by TOMTEC IMAGING SYSTEMS GMBH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/cmr+feature+tracking/10__1161_slash_circimaging__115__004091-82-14-21
Average 90 stars, based on 1 article reviews
cmr feature tracking software image-arena 4.6 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TOMTEC IMAGING SYSTEMS GMBH 2d cpa cmr feature tracking software
Representative <t>cardiovascular</t> <t>magnetic</t> <t>resonance</t> <t>(CMR)</t> images of a ) a patient with light chain (AL) amyloidosis demonstrating global left ventricular (LV) wall hypertrophy, pericardial effusion and both-sided pleural effusions, b Late gadolinium enhancement (LGE) pronounced in the subendocardial layers in cardiac amyloidosis (marked with a red line) and c ) long axis strain (LAS) measurement
2d Cpa Cmr Feature Tracking Software, supplied by TOMTEC IMAGING SYSTEMS GMBH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/2d+cpa+cmr+feature+tracking+software/pmc06704553-123-8-15
Average 90 stars, based on 1 article reviews
2d cpa cmr feature tracking software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

86
Circle Cardiovascular Imaging Inc cmr 42
Representative <t>cardiovascular</t> <t>magnetic</t> <t>resonance</t> <t>(CMR)</t> images of a ) a patient with light chain (AL) amyloidosis demonstrating global left ventricular (LV) wall hypertrophy, pericardial effusion and both-sided pleural effusions, b Late gadolinium enhancement (LGE) pronounced in the subendocardial layers in cardiac amyloidosis (marked with a red line) and c ) long axis strain (LAS) measurement
Cmr 42, supplied by Circle Cardiovascular Imaging Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/cmr42/pmc12605555-94-16-18
Average 86 stars, based on 1 article reviews
cmr 42 - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
NeoSoft LLC dedicated cmr postprocessing software suiteheart
Case 1 <t>CMR</t> ( A ) 3D Long axis view showing bileaflet prolapse. The prolapsed distance is measured as superior displacement of leaflet beyond mitral annulus ( orange arrows ) ( B ) Long-axis view, Longitudinal mitral annulus disjunction (MAD; green line ) length is measured from the junction of left atrial (LA) wall–posterior MV leaflet to the top of the left ventricular (LV) inferobasal wall during end systole ( C ). Same image as in ( B ) showing measurement of curling distance by tracing a line between the LA wall–posterior MV leaflet junction and top of LV inferobasal wall, and from this line, a perpendicular line to the lower limit of the mitral annulus during end-systole. ( D ) LV basal hypertrophy. The LV thickness of basal and mid segments of the inferolateral wall is measured at diastole on long axis view. Base-to-mid ratio: 2.7. 3D, three-dimensional; CMR, <t>cardiac</t> <t>magnetic</t> <t>resonance</t> imaging; MV, mitral valve.
Dedicated Cmr Postprocessing Software Suiteheart, supplied by NeoSoft LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/dedicated+cmr+postprocessing+software+suiteheart/pmc09705142-64-7-12
Average 90 stars, based on 1 article reviews
dedicated cmr postprocessing software suiteheart - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
NeoSoft LLC dedicated cmr post-processing software suiteheart
List of various cardiovascular pathologies along with patient demographic data where myocardial strain was used as an incremental diagnostic tool
Dedicated Cmr Post Processing Software Suiteheart, supplied by NeoSoft LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/cmr+image+analysis+software+suiteheart/pmc09705126-31-6-11
Average 90 stars, based on 1 article reviews
dedicated cmr post-processing software suiteheart - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Siemens AG cmr software argus
CONSORT flow diagram depicting the PRAMI <t>CMR</t> substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.
Cmr Software Argus, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/cmr+software+argus/pmc05256395-118-9-12
Average 90 stars, based on 1 article reviews
cmr software argus - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Medviso AB dedicated software segment cmr
CONSORT flow diagram depicting the PRAMI <t>CMR</t> substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.
Dedicated Software Segment Cmr, supplied by Medviso AB, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/dedicated+software+segment/pmc09937585-25-18-22
Average 90 stars, based on 1 article reviews
dedicated software segment cmr - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
KU Leuven dedicated software rightvol
CONSORT flow diagram depicting the PRAMI <t>CMR</t> substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.
Dedicated Software Rightvol, supplied by KU Leuven, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/rightvol/pmc06922070__hcg___12___e002656___s001-64-6-9
Average 90 stars, based on 1 article reviews
dedicated software rightvol - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Medviso AB software segment cmr
CONSORT flow diagram depicting the PRAMI <t>CMR</t> substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.
Software Segment Cmr, supplied by Medviso AB, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/segment+cmr+software/pm35585495-3-2-4
Average 90 stars, based on 1 article reviews
software segment cmr - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TOMTEC IMAGING SYSTEMS GMBH 2d cpa mr cardiac performance analysis
CONSORT flow diagram depicting the PRAMI <t>CMR</t> substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.
2d Cpa Mr Cardiac Performance Analysis, supplied by TOMTEC IMAGING SYSTEMS GMBH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/2d+cardiac+performance+analysis/pmc04683162-99-11-8
Average 90 stars, based on 1 article reviews
2d cpa mr cardiac performance analysis - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

86
Philips Healthcare dedicated cmr software analysis tool
CONSORT flow diagram depicting the PRAMI <t>CMR</t> substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.
Dedicated Cmr Software Analysis Tool, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/angiography+coronary+quantitative/10__32604_slash_chd__2023__029634-71-18-26
Average 86 stars, based on 1 article reviews
dedicated cmr software analysis tool - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Medviso AB segment cmr, version 3
CONSORT flow diagram depicting the PRAMI <t>CMR</t> substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.
Segment Cmr, Version 3, supplied by Medviso AB, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dedicated+cmr+software+analysis+tool/segment+version+1+9/pm37726513-52-1-7
Average 90 stars, based on 1 article reviews
segment cmr, version 3 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Representative cardiovascular magnetic resonance (CMR) images of a ) a patient with light chain (AL) amyloidosis demonstrating global left ventricular (LV) wall hypertrophy, pericardial effusion and both-sided pleural effusions, b Late gadolinium enhancement (LGE) pronounced in the subendocardial layers in cardiac amyloidosis (marked with a red line) and c ) long axis strain (LAS) measurement

Journal: Journal of Cardiovascular Magnetic Resonance

Article Title: Prognostic value of novel imaging parameters derived from standard cardiovascular magnetic resonance in high risk patients with systemic light chain amyloidosis

doi: 10.1186/s12968-019-0564-1

Figure Lengend Snippet: Representative cardiovascular magnetic resonance (CMR) images of a ) a patient with light chain (AL) amyloidosis demonstrating global left ventricular (LV) wall hypertrophy, pericardial effusion and both-sided pleural effusions, b Late gadolinium enhancement (LGE) pronounced in the subendocardial layers in cardiac amyloidosis (marked with a red line) and c ) long axis strain (LAS) measurement

Article Snippet: CMR myocardial global strain analyses were performed using dedicated 2D CPA CMR Feature tracking software (TomTec Imaging Systems, Munich, Germany).

Techniques:

Demographics and  cardiovascular magnetic resonance   (CMR)  data of patients with light-chain amyloidosis ( n = 74), with and without reaching the composite endpoints during the follow-up of 2 years

Journal: Journal of Cardiovascular Magnetic Resonance

Article Title: Prognostic value of novel imaging parameters derived from standard cardiovascular magnetic resonance in high risk patients with systemic light chain amyloidosis

doi: 10.1186/s12968-019-0564-1

Figure Lengend Snippet: Demographics and cardiovascular magnetic resonance (CMR) data of patients with light-chain amyloidosis ( n = 74), with and without reaching the composite endpoints during the follow-up of 2 years

Article Snippet: CMR myocardial global strain analyses were performed using dedicated 2D CPA CMR Feature tracking software (TomTec Imaging Systems, Munich, Germany).

Techniques: Transplantation Assay

Case 1 CMR ( A ) 3D Long axis view showing bileaflet prolapse. The prolapsed distance is measured as superior displacement of leaflet beyond mitral annulus ( orange arrows ) ( B ) Long-axis view, Longitudinal mitral annulus disjunction (MAD; green line ) length is measured from the junction of left atrial (LA) wall–posterior MV leaflet to the top of the left ventricular (LV) inferobasal wall during end systole ( C ). Same image as in ( B ) showing measurement of curling distance by tracing a line between the LA wall–posterior MV leaflet junction and top of LV inferobasal wall, and from this line, a perpendicular line to the lower limit of the mitral annulus during end-systole. ( D ) LV basal hypertrophy. The LV thickness of basal and mid segments of the inferolateral wall is measured at diastole on long axis view. Base-to-mid ratio: 2.7. 3D, three-dimensional; CMR, cardiac magnetic resonance imaging; MV, mitral valve.

Journal: The Indian Journal of Radiology & Imaging

Article Title: Mitral Annulus Disjunction and Arrhythmic Mitral Valve Prolapse: Emerging Role of Cardiac Magnetic Resonance Imaging in the Workup

doi: 10.1055/s-0042-1754357

Figure Lengend Snippet: Case 1 CMR ( A ) 3D Long axis view showing bileaflet prolapse. The prolapsed distance is measured as superior displacement of leaflet beyond mitral annulus ( orange arrows ) ( B ) Long-axis view, Longitudinal mitral annulus disjunction (MAD; green line ) length is measured from the junction of left atrial (LA) wall–posterior MV leaflet to the top of the left ventricular (LV) inferobasal wall during end systole ( C ). Same image as in ( B ) showing measurement of curling distance by tracing a line between the LA wall–posterior MV leaflet junction and top of LV inferobasal wall, and from this line, a perpendicular line to the lower limit of the mitral annulus during end-systole. ( D ) LV basal hypertrophy. The LV thickness of basal and mid segments of the inferolateral wall is measured at diastole on long axis view. Base-to-mid ratio: 2.7. 3D, three-dimensional; CMR, cardiac magnetic resonance imaging; MV, mitral valve.

Article Snippet: Data analysis and postprocessing was performed on dedicated CMR postprocessing software (suiteHEART; NeoSoft LLC, Wisconsin, United States).

Techniques: Magnetic Resonance Imaging

Case 2 CMR. ( A ) Two-chamber view demonstrating bileaflet mitral valve prolapse with prolapse distance measurements ( orange arrows ). ( B ) Note regurgitant jet from mitral regurgitation ( green arrow ) ( C ) Note the separation of LV myocardium from mitral annulus ( green line : MAD distance). ( D ) Curling of LV myocardium seen in two-chamber view with quantitative measurement of curling distance ( yellow arrow ). ( E ) LV basal hypertrophy Base: Mid LV thickness ratio of 2:1. ( F ) Focal LGE involving the posterobasal wall of LV myocardium. ( G ) Color coded feature tracking map in long axis views with global longitudinal strain curve depicting reduction in GLS. CMR, cardiac magnetic resonance imaging; GLS, global longitudinal strain; LV, left ventricle; MAD, mitral annulus disjunction.

Journal: The Indian Journal of Radiology & Imaging

Article Title: Mitral Annulus Disjunction and Arrhythmic Mitral Valve Prolapse: Emerging Role of Cardiac Magnetic Resonance Imaging in the Workup

doi: 10.1055/s-0042-1754357

Figure Lengend Snippet: Case 2 CMR. ( A ) Two-chamber view demonstrating bileaflet mitral valve prolapse with prolapse distance measurements ( orange arrows ). ( B ) Note regurgitant jet from mitral regurgitation ( green arrow ) ( C ) Note the separation of LV myocardium from mitral annulus ( green line : MAD distance). ( D ) Curling of LV myocardium seen in two-chamber view with quantitative measurement of curling distance ( yellow arrow ). ( E ) LV basal hypertrophy Base: Mid LV thickness ratio of 2:1. ( F ) Focal LGE involving the posterobasal wall of LV myocardium. ( G ) Color coded feature tracking map in long axis views with global longitudinal strain curve depicting reduction in GLS. CMR, cardiac magnetic resonance imaging; GLS, global longitudinal strain; LV, left ventricle; MAD, mitral annulus disjunction.

Article Snippet: Data analysis and postprocessing was performed on dedicated CMR postprocessing software (suiteHEART; NeoSoft LLC, Wisconsin, United States).

Techniques: Magnetic Resonance Imaging

CMR planning for assessment of mitral valve. ( A ) CMR short axis view at the level of mitral valve showing anatomy of mitral valve. A1, A2, and A3 scallops in the anterior leaflet. P1, P2, and P3 scallops in the posterior leaflet. ( B ) Modified left ventricular outflow tract view. Contiguous stack of cine images perpendicular to the mitral commissures transecting the principal line of coaptation to visualize and assess all the mitral scallops A1–P1, A2–P2, and A3–P3. ( C ) Additional/alternative slices perpendicular to the coaptation plane of the valve leaflets ( yellow and/or purple lines ) ( D ) For circumferential assessment of annular plane, six left ventricular long-axis cine slices are acquired at every 30degrees. The first projection was aligned through the superior right ventricular free wall insertion into the septum, and was defined as 0° in the annular plane, followed by clockwise labeling of the long-axis slices. CMR, cardiac magnetic resonance imaging.

Journal: The Indian Journal of Radiology & Imaging

Article Title: Mitral Annulus Disjunction and Arrhythmic Mitral Valve Prolapse: Emerging Role of Cardiac Magnetic Resonance Imaging in the Workup

doi: 10.1055/s-0042-1754357

Figure Lengend Snippet: CMR planning for assessment of mitral valve. ( A ) CMR short axis view at the level of mitral valve showing anatomy of mitral valve. A1, A2, and A3 scallops in the anterior leaflet. P1, P2, and P3 scallops in the posterior leaflet. ( B ) Modified left ventricular outflow tract view. Contiguous stack of cine images perpendicular to the mitral commissures transecting the principal line of coaptation to visualize and assess all the mitral scallops A1–P1, A2–P2, and A3–P3. ( C ) Additional/alternative slices perpendicular to the coaptation plane of the valve leaflets ( yellow and/or purple lines ) ( D ) For circumferential assessment of annular plane, six left ventricular long-axis cine slices are acquired at every 30degrees. The first projection was aligned through the superior right ventricular free wall insertion into the septum, and was defined as 0° in the annular plane, followed by clockwise labeling of the long-axis slices. CMR, cardiac magnetic resonance imaging.

Article Snippet: Data analysis and postprocessing was performed on dedicated CMR postprocessing software (suiteHEART; NeoSoft LLC, Wisconsin, United States).

Techniques: Modification, Labeling, Magnetic Resonance Imaging

List of various cardiovascular pathologies along with patient demographic data where myocardial strain was used as an incremental diagnostic tool

Journal: The Indian Journal of Radiology & Imaging

Article Title: Myocardial Strain Imaging Using Feature Tracking Method of Cardiac MRI: Our Initial Experience of This Novel Parameter as an Additional Diagnostic Tool

doi: 10.1055/s-0042-1748760

Figure Lengend Snippet: List of various cardiovascular pathologies along with patient demographic data where myocardial strain was used as an incremental diagnostic tool

Article Snippet: Post-processing was performed using commercially available dedicated CMR post-processing software (suiteHEART, NeoSoft LLC, Wisconsin, United States).

Techniques: Diagnostic Assay

CONSORT flow diagram depicting the PRAMI CMR substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.

Journal: Heart

Article Title: Infarct size and left ventricular remodelling after preventive percutaneous coronary intervention

doi: 10.1136/heartjnl-2015-308660

Figure Lengend Snippet: CONSORT flow diagram depicting the PRAMI CMR substudy. A total of 219 patients were enrolled in Glasgow and Newcastle and 84 of these patients gave informed consent to participate in the CMR substudy. CMR, cardiac magnetic resonance; PCI, percutaneous coronary intervention; PRAMI, preventive angioplasty in myocardial infarction.

Article Snippet: Image analysis was performed using a core laboratory with dedicated CMR software (Siemens Syngo VE32D and Argus, Erlangen, Germany).

Techniques:

Late gadolinium enhancement imaging of preventive angioplasty in myocardial infarction (PRAMI) cardiac magnetic resonance (CMR) substudy participants depicting non-culprit-artery infarcts, with corresponding end-diastolic cine frame. Red crosses indicate culprit-artery-territory infarct; blue crosses indicate non-culprit-artery-territory infarct. Preventive percutaneous coronary intervention (PCI): (A, B) patient with lateral ST elevation on ECG underwent PCI to the circumflex and to the mid-left anterior descending coronary artery (LAD). Late enhancement revealed an additional region of scar in the anteroseptal wall. (C, D) Participant with an inferior ST-elevation myocardial infarction (STEMI) with PCI to the right coronary artery (RCA) underwent CMR which revealed an additional infarct in the anterolateral region. This patient underwent PCI to all three coronary arteries. (E, F) This patient had PCI to the RCA for an inferior STEMI and PCI to the circumflex artery. Late enhancement revealed a small focus of scarring in the basal anterolateral segment. (G, H) Inferior STEMI with PCI to the culprit RCA and additional PCI to the circumflex. Late enhancement revealed a small infarct in the basal anterolateral segment. Culprit-artery-only PCI: (I, J) participant presented with an anterior STEMI. Late gadolinium enhancement revealed additional inferolateral infarct. (K, L) Anterior STEMI, with late enhancement in the anteroseptal region and an additional area in the anterolateral segment.

Journal: Heart

Article Title: Infarct size and left ventricular remodelling after preventive percutaneous coronary intervention

doi: 10.1136/heartjnl-2015-308660

Figure Lengend Snippet: Late gadolinium enhancement imaging of preventive angioplasty in myocardial infarction (PRAMI) cardiac magnetic resonance (CMR) substudy participants depicting non-culprit-artery infarcts, with corresponding end-diastolic cine frame. Red crosses indicate culprit-artery-territory infarct; blue crosses indicate non-culprit-artery-territory infarct. Preventive percutaneous coronary intervention (PCI): (A, B) patient with lateral ST elevation on ECG underwent PCI to the circumflex and to the mid-left anterior descending coronary artery (LAD). Late enhancement revealed an additional region of scar in the anteroseptal wall. (C, D) Participant with an inferior ST-elevation myocardial infarction (STEMI) with PCI to the right coronary artery (RCA) underwent CMR which revealed an additional infarct in the anterolateral region. This patient underwent PCI to all three coronary arteries. (E, F) This patient had PCI to the RCA for an inferior STEMI and PCI to the circumflex artery. Late enhancement revealed a small focus of scarring in the basal anterolateral segment. (G, H) Inferior STEMI with PCI to the culprit RCA and additional PCI to the circumflex. Late enhancement revealed a small infarct in the basal anterolateral segment. Culprit-artery-only PCI: (I, J) participant presented with an anterior STEMI. Late gadolinium enhancement revealed additional inferolateral infarct. (K, L) Anterior STEMI, with late enhancement in the anteroseptal region and an additional area in the anterolateral segment.

Article Snippet: Image analysis was performed using a core laboratory with dedicated CMR software (Siemens Syngo VE32D and Argus, Erlangen, Germany).

Techniques: Imaging